Mounting Dosing pump Dosi-Pump

Fixing the pump to the container

Before purchasing please consider:

The Dosing pump is mounted by you on your existing container closure. Take the diameter of the drillhole from the table.

Description

Drillhole  Ø     Item number

Dosing pump Dosi-Pump 4 ml

21 mm 5607-1004

Dosing pump Dosi-Pump 30 ml

28,5 mm

5607-2030

Dosing pump Dosi-Pump 30 ml, fixed feeding tube

22 mm 5607-3030

Dosing pump Dosi-Pump 100 ml, fixed feeding tube

28,5 mm 5607-4100

Dosing pump Dosi-Pump 250 ml, fixed feeding tube

28,5 mm 5607-5250

 

The "Dosing pump Dosi-Pump 4 ml" (5607-1004) can also be mounted without drilling.

The "Dosing pump Dosi-Pump 100 ml, fixed feeding tube" (5607-4100) and "Dosing pump Dosi-Pump 250 ml, fixed feeding tube" (5607-5250) can no longer be dismantled after mounting.

 

Mounting

1. Drilling drillhole

Drill the hole in the container closure on which you want to mount the Pump. 

(Drill hole's diameter see the table above.)

2. Loosening threaded nut

Screw threaded nut counterclockwise to loosen it from the Dosi-Pump.

3. Inserting pump 

Insert the Dosi-Pump from above through the drilling hole of the container closure.

4. Fixing Dosi-Pump

Fix the Dosi-Pump from below with the threaded nut on the container closure.

5. Attaching container closure

Attach the container closure to the container. The Dosi-Pump is ready for use.

Dosing Pumps Dosi-Pump